Skip to content

FAQ & Troubleshooting

Common issues and solutions when using Valyte.


Installation

valyte: command not found

Cause: The valyte script is not on your PATH. This usually happens when pip installs to a user-local directory.

Fix:

# Check if valyte is installed
pip show valyte

# Option 1: Install with --user and add to PATH
pip install --user valyte
export PATH="$HOME/.local/bin:$PATH"  # Add to your .bashrc or .zshrc

# Option 2: Install in a virtual environment (recommended)
python -m venv venv
source venv/bin/activate
pip install valyte

ModuleNotFoundError: No module named 'valyte'

Cause: You may have multiple Python installations, and valyte is installed in a different one.

Fix: Ensure you're using the same Python that pip installed to:

python -m valyte.cli --help
# or
python -m pip install valyte

Band structure

My k-point labels are wrong or missing

Cause: You ran the band calculation with the original POSCAR instead of the standardized cell.

Fix: After generating k-points, always use the standardized cell:

valyte band kpt-gen
cp POSCAR_standard POSCAR    # Use this for the band calculation

The k-path is defined for the standardized primitive cell. Using a different cell orientation will produce incorrect or mismatched labels.

My tricolor plot is all one color

Cause: VASP did not write orbital projections into vasprun.xml.

Fix: Add LORBIT = 11 to your INCAR and re-run the calculation. This writes the projected eigenvalues that tricolor mode needs.

# In INCAR
LORBIT = 11

ValueError: No spin channels found for spin-resolved mode

Cause: You used --spin-resolved on a non-spin-polarized calculation.

Fix: Either: - Run VASP with ISPIN = 2 in your INCAR for a spin-polarized calculation, or - Use valyte band without --spin-resolved for non-magnetic systems

Valyte will automatically fall back to a standard plot with a warning.

ValueError: No projected_magnetisation data found

Cause: You used --spin-texture on a collinear or non-SOC calculation.

Fix: Spin texture requires a non-collinear calculation:

# In INCAR
LSORBIT = .TRUE.
LORBIT = 11

Density of states

The DOS looks noisy or has sharp spikes

Cause: Insufficient k-point sampling in the SCF calculation.

Fix: Increase the k-point density. For metals, a very dense grid (e.g., k-spacing < 0.03 in 2π/Å) is often needed for smooth DOS.

Legend is not showing

Cause: The --legend-cutoff threshold is hiding the legend because the projected contributions are small relative to the total DOS.

Fix: Lower the cutoff:

valyte dos -e Fe O --legend-cutoff 0.01

Effective mass

Error: This does not appear to be a line-mode band calculation

Cause: You're pointing valyte effmass at a self-consistent (SCF) calculation rather than a non-self-consistent band structure calculation.

Fix: Run a band structure calculation first:

  1. Generate k-points: valyte band kpt-gen
  2. Copy POSCAR_standard to POSCAR
  3. Run VASP with ICHARG = 11 and the generated line-mode KPOINTS
  4. Then run valyte effmass

Effective masses are unreasonably large or negative

Cause: The parabolic approximation breaks down for non-parabolic bands (narrow-gap semiconductors, d-bands, strong SOC).

Fix:

  • Try reducing the fitting window: valyte effmass --npoints 2
  • Use --plot to visually inspect the parabolic fit
  • Consider whether a parabolic effective mass is physically meaningful for your system

POTCAR

ValueError: No POTCAR for element ... or pymatgen errors

Cause: Pymatgen cannot find your VASP pseudopotential files.

Fix: Set up ~/.pmgrc.yaml:

PMG_VASP_PSP_DIR: /path/to/your/pseudopotentials

The directory should contain subdirectories like POT_GGA_PAW_PBE/, POT_GGA_PAW_PBE_52/, etc. See the pymatgen documentation.


Convergence

FileNotFoundError: OSZICAR not found

Cause: Valyte cannot find OSZICAR in the specified directory.

Fix:

# Point to the correct directory
valyte converge /path/to/calculation/directory

# Or run from the calculation directory
cd /path/to/calculation
valyte converge

Force panel shows no data

Cause: OUTCAR is missing or incomplete.

Fix: The --forces and --stress flags require OUTCAR. Without it, only energy and ΔE panels (from OSZICAR) are available. Make sure the OUTCAR file exists in the same directory as OSZICAR.


General

Can I use Valyte on a remote cluster over SSH?

Yes. Valyte uses matplotlib's Agg backend by default, so it does not require a display. Plots are saved to files.

For a quick convergence check without generating a plot:

valyte converge --no-plot

How do I export data for custom plotting?

Every plot command supports --save-data:

valyte dos --save-data           # → valyte_dos.dat
valyte band --save-data          # → valyte_band.dat
valyte effmass --save-data       # → valyte_effmass.dat
valyte converge --save-data      # → valyte_converge.dat

These are plain-text, whitespace-delimited files that can be loaded into any plotting tool (Python, MATLAB, gnuplot, Origin, etc.).

Something else is broken

Open an issue with:

  • Valyte version (pip show valyte)
  • Python version (python --version)
  • The full error traceback
  • The command you ran